Pengaruh Sudut Pengarah Aliran Pada Turbin Air Crossflow Tingkat Dua Terhadap Putaran dan Daya


The Effect of Flow Guide Angle on a Level Two Crossflow Water Turbine on Rotation and Power


  • (1)  Satria Candra Laksmana            Teknik Mesin, Universitas Muhammadiyah Sidoarjo  
            Indonesia

  • (2) * A'rasy Fahruddin            Teknik Mesin, Universitas Muhammadiyah Sidoarjo  
            Indonesia

  • (3)  Ali Akbar            Teknik Mesin, Universitas Muhammadiyah Sidoarjo  
            Indonesia

    (*) Corresponding Author

Abstract

The potential of hydro energy is very large both for large scale and for small scale. Until now, the need for energy continues to increase, so that energy is a very important element in the development of a country or a region. Cross-flow turbines are one type of turbine that is often used for PLTMH. In this study planning a cross-flow water turbine applied to the height and amount of water per second in the irrigation channel water flow, this water flow will rotate the turbine shaft to produce mechanical energy. With variations in the direction of the turbine flow direction, namely 30o, 35o, and 40o, and the same variation of water discharge 10,5 L / s, 21 L / s and 31,5 L / s to determine the effect on the rotation and the power produced. In this study with 12 turbine blades, 30o blade angle, 40o flow direction angle, and 31.5 L / s water discharge obtained the highest first stage turbine rotation value is 478 rpm. Whereas at the flow direction angle of 30o with the same water discharge which is 31.5 L / s so that the first stage of the turbine is obtained is 296 rpm.

References

Mafruddin, D. Irawan, “Pembuatan Turbin Mikrohidro Tipe Cross-Flow Sebagai Pembangkit Listrik di Desa Bumi Nabung Timur,” Jurnal Turbo, vol. 3, no. 2, 2014.

Verdy A Koehuan, Agustinus Sampealo, “Analisis Desain Turbin Air Tipe Aliran Silang (Cross Flow) dan Aplikasinya di Desa Werel Kabupaten Ngada-NTT,” Lontar Jurnal Teknik Mesin Undana, Vol. 2, No.1, 2015.

Ali Khomsah, Efrita Arfah Zuliari, “Analisa Teori: Performa Turbin Cross Flow Sudu Bambu 5” sebagai Penggerak Mula Generator Induksi 3 Fasa,” Seminar Nasional Sains dan Teknologi Terapan III, Institut Teknologi Adhi Tama Surabaya, 2015.

A. Fahruddin and Mulyadi, “Rancang Bangun Alat Uji Head Losses dengan Variasi Debit dan Jarak Elbow 90˚ Untuk Sistem Perpipaan yang Efisien,” J. Turbo, vol. 7, no. 1, pp. 32–35, 2018.

A. Maidangkay, R. Soenoko, and S. Wahyudi, “Pengaruh sudut pengarah aliran dan jumlah sudu radius berengsel luar roda tunggal terhadap kinerja tubin kinetik,” Jurnal Rekayasa Mesin, Vol.5, No. 2, 2014.

Pramesti, Yasinta Sindy, “Analisa pengaruh sudut sudu terhadap kinerja turbin kinetik poros horisontal dan vertical,“ Jurnal Mesin Nusantara, vol. 1, no. 1, p. 51-59, 2018.

Yudi Setiawan, Irfan Wahyudi, Erwin Nandes,”Unjuk kerja turbin air tipe cross flow dengan variasi debit air dan sudut serang nosel,” Jurnal Turbo, Vol. 2 No. 1, 2016.

Picture in here are illustration from public domain image (License) or provided by the author, as part of their works
Published
2018-06-29
 
Section
Articles